MZ |
1 deg. ion is at RT but hydrocarbs interfere with 2 deg. ion eval |
GL |
2,3,7,8-TCDF results have been confirmed on a DB-225 column |
DN |
2-Sigma Error |
RZ |
4-BFB is outside acceptance limits. All other QC parameters in control, therefore data was approved. |
T5 |
<100g avail for TCLP extrctn-vol of extrct adjusted per procd |
GU |
>10% breakthrough in second carbon col. due to matrix effects |
H |
A holding time violation has occurred. |
M |
A matrix effect is present. |
DD |
A precipitate formed in the extract during sample preparation |
SG |
A silica gel cleanup procedure was performed. |
OE |
Absent |
LJ |
Acid surr. above limits. Data accept. based on other 2 acid surr. |
LI |
Acid surr. below limits. Data accept. based on other 2 acid surr. |
OF |
Aggressive |
GX |
All reporting limits raised due to high conc. dissolved solids |
OJ |
All samples & QC in batch analyzed to meet high-level rep limits |
OS |
Amount detected is less than the Lower Calibration Limit |
CX |
Analysis was performed on a 0.01N HCl extract |
CV |
Analysis was performed on a 2M KCl extract |
CY |
Analysis was performed on a deionized water extract |
GY |
Analyte assoc. with sample processing & analysis in lab environ. |
CP |
Analyte conc. detectable, but less than 10 times blank conc. |
CQ |
Analyte conc. greater that 10 times the blank conc. |
CJ |
Analyte concentration is in excess of the instrument calibration |
GI |
Analyte confirmed by GC/MS |
PQ |
Analyte detectable in MB, but less than 5% of sample result |
BJ |
Analyte detected in blank and sample |
PU |
Analyte detected in blank but not in associated samples |
UL |
Analyte detected in laboratory blank. |
MH |
Analyte determined to be in travel blank before left lab |
QQ |
Analyte found in travel blank but not in associated samples. |
ID |
Analyte identified by RT & presence of single mass ion |
FI |
Analyte in field sample and associated blank |
HC |
Analyte is this compound or an isomer |
OA |
Analyte over-range when run undiluted. Diluted result below PQL. |
JA |
Analyte positively identified but quanitation is an estimate |
FX |
Analyte present in the instrument blank |
MB |
Analyte present in the method blank |
HL |
Analyte recovery above established limit |
HM |
Analyte recovery below established limit |
QF |
Analyte recovery outside critera |
UU |
Analyte value 20 times less than level determined in method blank. |
LS |
Analyte%RSD>meth. calib.accept.limits. Avg%RSD for all meet SW846 |
WA |
Analytes would have been detected even with low recovery. |
GG |
Analytical results not reliable for this common lab contaminant |
IZ |
Analytical results not reliable--potential samp. contain. contam. |
HT |
Analytical value calculated using results from associated tests |
UW |
Analyzed by ICP-MS DRC |
UA |
Average. |
LL |
B/N surr. above limits. Data accept. based on other 2 B/Nsurr. |
LK |
B/N surr. below limits. Data accept. based on other 2 B/Nsurr. |
WO |
Background subtracted from the QC samples and the client's sample(s). |
DS |
Batch Quality Assurance data from another project |
UI |
Below the LRL and above the LT-MDL. |
HJ |
Blank spike recovery not within control limits |
HK |
Calcium carbonate is greater than 5% of the sample weight |
CAL |
Calculated Value |
IC |
Calib. verif. is within method limits but outside contract limits |
CRF |
Calibration Response Factor |
IJ |
Calibrtn. verif. recov. above method CL for this analyte |
IH |
Calibrtn. verif. recov. below method CL for this analyte |
XY |
Capped and allowed to equilibrate 24 hrs before sampling. |
FE |
Carbon-labeled int. std. with s/n ratio of < 10:1 |
CW |
Carbonate alkalinity is zero because the sample's pH is < 8.3 |
TZ |
Carrier exceeds control limit. |
YA |
Cation and anion sum |
IB |
CCV recovery above limit; analyte not detected |
LF |
Chrom. pattern in diesel range more closely resembles kerosene. |
RX |
Chrom. pattern matches std. but heavier hydrocarbs. also present |
RW |
Chrom. pattern matches std. but lighter hydrocarbs. also present |
HD |
Chromat. profile inconsistent with pattern(s) of ref. fuel stnds. |
FY |
Chromatogram not typical of calibration standard |
IU |
Chromatogram resembles Aviation Gas-100LL - no Toluene detected |
QD |
Chromatographic pattern does not resemble fuel standard |
WL |
Cited ADHS licensed method does not contain this analyte as part of the method compound list. |
PN |
Closing calib outside limits-ave %diff for analytes met 15% req. |
PM |
Closing calib. for analyte out of limits due to instru. contam. |
DO |
Coelution |
GA |
Components not separable by this method; quantified together |
QO |
Compound did not meet ID guidelines. Addit. GC/MS ID params used. |
DY |
Compound identified is an analysis at a secondary dilution factor |
EP |
Compound quantitated at > 1000x dilution factor |
EO |
Compound quantitated at a 1000x dilution factor |
EL |
Compound quantitated at a 100x dilution factor |
EI |
Compound quantitated at a 10x dilution factor |
EM |
Compound quantitated at a 200x dilution factor |
EJ |
Compound quantitated at a 20x dilution factor |
EG |
Compound quantitated at a 2x dilution factor |
EN |
Compound quantitated at a 500x dilution factor |
EK |
Compound quantitated at a 50x dilution factor |
EH |
Compound quantitated at a 5x dilution factor |
EF |
Compound quantitated at a different dilution |
BL |
Compound unidentified at a second dilution |
TB |
Conc. could not be determined due to high dissolved solids conc. |
CQA |
Concentration not reported for QA sample only Percent Recovery or RPD reported. |
ED |
Concentration of total analyte ND; therefore this analyte is ND |
BD |
Concentration value greater than 25% difference between columns |
LE |
Confirmation not performed. Analyte present in historical data |
LD |
Confirmatory analysis not performed as required by the method. |
LB |
Confirmatory analysis past hold time. Orig.result not confirmed. |