MZ 1 deg. ion is at RT but hydrocarbs interfere with 2 deg. ion eval
GL 2,3,7,8-TCDF results have been confirmed on a DB-225 column
DN 2-Sigma Error
RZ 4-BFB is outside acceptance limits. All other QC parameters in control, therefore data was approved.
T5 <100g avail for TCLP extrctn-vol of extrct adjusted per procd
GU >10% breakthrough in second carbon col. due to matrix effects
H A holding time violation has occurred.
M A matrix effect is present.
DD A precipitate formed in the extract during sample preparation
SG A silica gel cleanup procedure was performed.
OE Absent
LJ Acid surr. above limits. Data accept. based on other 2 acid surr.
LI Acid surr. below limits. Data accept. based on other 2 acid surr.
OF Aggressive
GX All reporting limits raised due to high conc. dissolved solids
OJ All samples & QC in batch analyzed to meet high-level rep limits
OS Amount detected is less than the Lower Calibration Limit
CX Analysis was performed on a 0.01N HCl extract
CV Analysis was performed on a 2M KCl extract
CY Analysis was performed on a deionized water extract
GY Analyte assoc. with sample processing & analysis in lab environ.
CP Analyte conc. detectable, but less than 10 times blank conc.
CQ Analyte conc. greater that 10 times the blank conc.
CJ Analyte concentration is in excess of the instrument calibration
GI Analyte confirmed by GC/MS
PQ Analyte detectable in MB, but less than 5% of sample result
BJ Analyte detected in blank and sample
PU Analyte detected in blank but not in associated samples
UL Analyte detected in laboratory blank.
MH Analyte determined to be in travel blank before left lab
QQ Analyte found in travel blank but not in associated samples.
ID Analyte identified by RT & presence of single mass ion
FI Analyte in field sample and associated blank
HC Analyte is this compound or an isomer
OA Analyte over-range when run undiluted. Diluted result below PQL.
JA Analyte positively identified but quanitation is an estimate
FX Analyte present in the instrument blank
MB Analyte present in the method blank
HL Analyte recovery above established limit
HM Analyte recovery below established limit
QF Analyte recovery outside critera
UU Analyte value 20 times less than level determined in method blank.
LS Analyte%RSD>meth. calib.accept.limits. Avg%RSD for all meet SW846
WA Analytes would have been detected even with low recovery.
GG Analytical results not reliable for this common lab contaminant
IZ Analytical results not reliable--potential samp. contain. contam.
HT Analytical value calculated using results from associated tests
UW Analyzed by ICP-MS DRC
UA Average.
LL B/N surr. above limits. Data accept. based on other 2 B/Nsurr.
LK B/N surr. below limits. Data accept. based on other 2 B/Nsurr.
WO Background subtracted from the QC samples and the client's sample(s).
DS Batch Quality Assurance data from another project
UI Below the LRL and above the LT-MDL.
HJ Blank spike recovery not within control limits
HK Calcium carbonate is greater than 5% of the sample weight
CAL Calculated Value
IC Calib. verif. is within method limits but outside contract limits
CRF Calibration Response Factor
IJ Calibrtn. verif. recov. above method CL for this analyte
IH Calibrtn. verif. recov. below method CL for this analyte
XY Capped and allowed to equilibrate 24 hrs before sampling.
FE Carbon-labeled int. std. with s/n ratio of < 10:1
CW Carbonate alkalinity is zero because the sample's pH is < 8.3
TZ Carrier exceeds control limit.
YA Cation and anion sum
IB CCV recovery above limit; analyte not detected
LF Chrom. pattern in diesel range more closely resembles kerosene.
RX Chrom. pattern matches std. but heavier hydrocarbs. also present
RW Chrom. pattern matches std. but lighter hydrocarbs. also present
HD Chromat. profile inconsistent with pattern(s) of ref. fuel stnds.
FY Chromatogram not typical of calibration standard
IU Chromatogram resembles Aviation Gas-100LL - no Toluene detected
QD Chromatographic pattern does not resemble fuel standard
WL Cited ADHS licensed method does not contain this analyte as part of the method compound list.
PN Closing calib outside limits-ave %diff for analytes met 15% req.
PM Closing calib. for analyte out of limits due to instru. contam.
DO Coelution
GA Components not separable by this method; quantified together
QO Compound did not meet ID guidelines. Addit. GC/MS ID params used.
DY Compound identified is an analysis at a secondary dilution factor
EP Compound quantitated at > 1000x dilution factor
EO Compound quantitated at a 1000x dilution factor
EL Compound quantitated at a 100x dilution factor
EI Compound quantitated at a 10x dilution factor
EM Compound quantitated at a 200x dilution factor
EJ Compound quantitated at a 20x dilution factor
EG Compound quantitated at a 2x dilution factor
EN Compound quantitated at a 500x dilution factor
EK Compound quantitated at a 50x dilution factor
EH Compound quantitated at a 5x dilution factor
EF Compound quantitated at a different dilution
BL Compound unidentified at a second dilution
TB Conc. could not be determined due to high dissolved solids conc.
CQA Concentration not reported for QA sample only Percent Recovery or RPD reported.
ED Concentration of total analyte ND; therefore this analyte is ND
BD Concentration value greater than 25% difference between columns
LE Confirmation not performed. Analyte present in historical data
LD Confirmatory analysis not performed as required by the method.
LB Confirmatory analysis past hold time. Orig.result not confirmed.