LNOTE
Name
Valid Value List
LNOTE NAME Sort ascending
WA Analytes would have been detected even with low recovery.
LS Analyte%RSD>meth. calib.accept.limits. Avg%RSD for all meet SW846
UU Analyte value 20 times less than level determined in method blank.
QF Analyte recovery outside critera
HM Analyte recovery below established limit
HL Analyte recovery above established limit
MB Analyte present in the method blank
FX Analyte present in the instrument blank
JA Analyte positively identified but quanitation is an estimate
OA Analyte over-range when run undiluted. Diluted result below PQL.
HC Analyte is this compound or an isomer
FI Analyte in field sample and associated blank
ID Analyte identified by RT & presence of single mass ion
QQ Analyte found in travel blank but not in associated samples.
MH Analyte determined to be in travel blank before left lab
UL Analyte detected in laboratory blank.
PU Analyte detected in blank but not in associated samples
BJ Analyte detected in blank and sample
PQ Analyte detectable in MB, but less than 5% of sample result
GI Analyte confirmed by GC/MS
CJ Analyte concentration is in excess of the instrument calibration
CQ Analyte conc. greater that 10 times the blank conc.
CP Analyte conc. detectable, but less than 10 times blank conc.
GY Analyte assoc. with sample processing & analysis in lab environ.
CY Analysis was performed on a deionized water extract
CV Analysis was performed on a 2M KCl extract
CX Analysis was performed on a 0.01N HCl extract
OS Amount detected is less than the Lower Calibration Limit
OJ All samples & QC in batch analyzed to meet high-level rep limits
GX All reporting limits raised due to high conc. dissolved solids
OF Aggressive
LI Acid surr. below limits. Data accept. based on other 2 acid surr.
LJ Acid surr. above limits. Data accept. based on other 2 acid surr.
OE Absent
SG A silica gel cleanup procedure was performed.
DD A precipitate formed in the extract during sample preparation
M A matrix effect is present.
H A holding time violation has occurred.
GU >10% breakthrough in second carbon col. due to matrix effects
T5 <100g avail for TCLP extrctn-vol of extrct adjusted per procd
RZ 4-BFB is outside acceptance limits. All other QC parameters in control, therefore data was approved.
DN 2-Sigma Error
GL 2,3,7,8-TCDF results have been confirmed on a DB-225 column
MZ 1 deg. ion is at RT but hydrocarbs interfere with 2 deg. ion eval