LNOTE
Name
Valid Value List
LNOTE Sort ascending NAME
QP Holding Time Immediate. Analyzed as close to receipt as possible
QO Compound did not meet ID guidelines. Addit. GC/MS ID params used.
QN Not to be reported for compliance purposes.
QM Result is reported below the CRDL for QC purposes only.
QG Individual analyte exceedances allowed per NELAC
QF Analyte recovery outside critera
QE Results in the diesel range are primarily from overlap heavy oil
QD Chromatographic pattern does not resemble fuel standard
QCM Quantitation began immediately following methanol peak
QCA Quantitation begun immed. before RT of tert-Butanol (TBA)
QB Unidentified hydrocarbons C9-C16
PZ Lighter hydrocarbons contributing to diesel range quantitation
PY SW3630C clean-up method performed
PX Sample extrctd beyond method hold time; within CA LUFT hold time
PW Lighter hydrocarbons contributed to motor oil range quantitation
PV Hydrocarbon result partly due to individ. peak(s) in quant. range
PU Analyte detected in blank but not in associated samples
PTV PTV = Purge Test Volume(s)
PT Hydrocarb. in req. fuel range, but doesn't resemble req. fuel
PS Heavier hydrocarbon than requested fuel
PR Preliminary result
PQ Analyte detectable in MB, but less than 5% of sample result
PP Dilutions for BOD failed criteria of 2mg/L diss. O depletion
PO Dilutions for BOD failed criteria of 1mg/L resid. diss. O
PN Closing calib outside limits-ave %diff for analytes met 15% req.
PM Closing calib. for analyte out of limits due to instru. contam.
PL Opening calib. for analyte out of limits due to instru. contam.
PK Opening calib verification standard outside acceptance criteria
PJ Result from re-extract/re-anal to confirm original MS/MSD result
PI Primary and confirm results varied by > than 40% RPD
PG The CC standard was outside of the acceptance criteria
PF Possible low bias due to CCV falling outside acceptance criteria
PE Possible high bias due to CCV falling outside acceptance criteria
PD Recommended storage temp of 4C exceeded prior to analysis
PC Sample taken from VOA vial with air bubble > 6mm diameter
PB The sample flash point is greater than 60 C (140 F)
PA Possible biogenic interference in detected hydrocarbons
P EPA Flag - > 25% D for detected concentrations between 2 columns
OZ Value is MTBE concentration present in the TPH Gas range.
OX Surrogate recorvery high due to matrix effects-refer to 2nd surr
OW Value is the result of an unidentified peak in the TPH Gas range.
OV Sample filtered in lab.
OU Sample diluted due to matrix inference. Reporting limits raised.
OT Sample spiked had pH <2, 2-Chloroethylvinylether degrades in acid
OS Amount detected is less than the Lower Calibration Limit
OR Heterotrophic bacteria colonies too numerous to count.
OQ Positive - (+)
ON MDL raised due to matrix interference.
OM EMPC/NDR Peak detected does not meet ratio criteria (elevated DL)
OL Result may be biased high due to carry over from prior analysis.
OK Incubation performed at 35C for 48hrs in plate count agar
OJ All samples & QC in batch analyzed to meet high-level rep limits
OI Rep.limit raised: carryover from contam samp earlier in analy seq
OH Report limit raised due to inadequate response at lowest cal.
OG Non-aggressive
OF Aggressive
OE Absent
OD Present
OC Result not bracketed by accept.cal check due to inst. malfunction
OB Surrogate and QC reported in ug/L.
OA Analyte over-range when run undiluted. Diluted result below PQL.
NG The reported result is a negative value
N EPA Flag - Presumptive evidence of a compound
MZ 1 deg. ion is at RT but hydrocarbs interfere with 2 deg. ion eval
MJ Sample was injected past the method specified tuning time period.
MI Hold time compliance not determined; no sample time on COC
MH Analyte determined to be in travel blank before left lab
MG This analyte is a suspected lab contaminant
MF Sample received chemically preserved - pH measured in lab > 2.0
ME Initial analysis within holding time but required confirmation
MD Identity of individual peak(s) confirmed by GCMS
MC Sample received unpreserved but analyzed within 7 days
MB Analyte present in the method blank
MA MS/MSD results unavail. due to failed CCV; batch accepted per LCS
M A matrix effect is present.
LZ Sample(stored at >0C,<4C) receipt >8hr HT. Anal w/in meth. HT
LY Sample(stored at >0C,<4C) prep > 8hr reg. HT. Anal. w/in meth. HT
LX Quantitated against diesel fuel.
LW Quantitated against gasoline.
LV Non-fuel pattern present.
LU Unquant. hydrocarbons in sample, outside reported carbon range.
LT RPD calc. does not provide useful info due to sample wt variation
LS Analyte%RSD>meth. calib.accept.limits. Avg%RSD for all meet SW846
LR LCS recovery below method control limits.
LQ LCS recovery above method control limits.
LP LCS rec.above meth. control limits. Analyte ND. Data not impacted
LO MS and/or MSD result unavailable. Batch accept. based on LCS rec.
LN MS and/or MSD below acceptance limits. See Blank Spike(LCS).
LM MS and/or MSD above acceptance limits. See Blank Spike(LCS).
LL B/N surr. above limits. Data accept. based on other 2 B/Nsurr.
LK B/N surr. below limits. Data accept. based on other 2 B/Nsurr.
LJ Acid surr. above limits. Data accept. based on other 2 acid surr.
LI Acid surr. below limits. Data accept. based on other 2 acid surr.
LH Surrogate recovery above the acceptance limits.
LG Surrogate recovery below the acceptance limits.
LF Chrom. pattern in diesel range more closely resembles kerosene.
LE Confirmation not performed. Analyte present in historical data
LD Confirmatory analysis not performed as required by the method.
LC Original analysis a positive result. Reanalysis did not confirm.
LB Confirmatory analysis past hold time. Orig.result not confirmed.