LNOTE
Name
Valid Value List
LNOTE Sort ascending NAME
YL Sample oxidized in the sample bottle with BrCl within 28 days of collect (extends hold time 90 days)
YK Reporting limit increased due to sample foaming.
YJ No sample was taken due to lack of access.
YH Value less than reporting limit; may be estimated or non-detect.
YG Sample fails ion ratio criteria low.
YF Sample fails ion ratio criteria high.
YE Excluding molybdenum disulfide, MoS2
YD Excluding barite, Ba SO4.
YC Dissociated ions may elevate this value (Ca+2, SO4-2 etc.)
YB Not Requested/Not Required.
YA Cation and anion sum
XZ No sample taken due to damaged probe.
XY Capped and allowed to equilibrate 24 hrs before sampling.
XW Purged
XV Sample acidified to pH <2 and allowed to sit 24 hours before further processing.
XT Sample was received unpreserved. Sample preserved by the laboratory prior to preparation.
XR The concentration is less than 5% of the sample result, which is neglible according to the method
XQ The concentration of the analyte is an estimated value above the calibration range of the instrument
XP The compound co-eluted with PCB-156
XO The compound co-eluted with other compounds
XN MS RPD Fail and Sample Size Diff >10%.
XM MS/MSD RPD exceeds control limits due to sample size difference.
XL Elevated detection limits do not meet llimits specified in QAPP.
XK Outside client's test acceptance limits, but within laboratory calculated QC limits.
XJ Hydrocarbon response in Stoddard solvent range but does not resemble Stoddard solvent.
XI Hydrocarbon response in motor oil range but does not resemble motor oil.
XH High bias in QC sample does not affect result since analyte not detected or below reporting limit.
XG Lighter than water immiscible sheen is present.
XF Possible aged fuel.
XE Liquid sample that contains greater than 5 volume % sediment.
XD Sample diluted due to high organic content.
XC Total Threshold Limit Concentration (TTLC)
XB Heavier gasoline range compounds are significant. Possilbly aged gasoline.
XA No recognizable pattern.
WZ Medium boling point pattern that does not match diesel.
WY Oil range compounds are significant.
WX Gasoline range compounds are significant.
WV Diesel range compounds are significant.
WU Unidentified peak(s) present.
WT Strongly aged gasoline or diesel range compounds are significant.
WS Gasoline range compounds having broad peaks are significant.Possibly biologically altered gasoline.
WR The positive result is an atypical pattern for analysis.
WQ Duplicate precision calculation not required, base concentration < 3X MDL
WP Spike amount added < 30% of base concentration
WO Background subtracted from the QC samples and the client's sample(s).
WN Target analyte was detected in the method blank at or above the reporting limit.
WM Tentatively identified compound concentration is estimated and based on closest internal standard.
WL Cited ADHS licensed method does not contain this analyte as part of the method compound list.
WK Samples were received and filtered past official holdling time.
WJ LCS target analytes within acceptance limits.
WI The CCV for these samples was within acceptance limits.
WH Sample composited in laboratory at client request.
WG This batch does not include a LCS for this parameter.
WF Samples showed no detectable levels of analyte and were not subjected to silica gel procedure.
WE Sample filtered immediately upon receipt by the laboratory.
WD Positive result confirmed by a second detector.
WC Data accepted.
WB No detectable levels of analyte in samples.
WA Analytes would have been detected even with low recovery.
VYC Val. Qual.: Not independ validated-subject to revision
VYB Val. Qual.: Specific issue independ validated-subject to revision
VYA Val. Qual.: Independently validated - subject to revision
VUJ Val. Qual.: MDL and EQL may be biased low
VUB Val. Qual.: Should be considered non-detect; final result now MDL
VU Val. Qual.: Compound analyzed for but not detected
VTB Val. Qual.: Analyte detected in associated trip blank sample
VSR Val. Qual.: Semi-quantitative result
VSL Val. Qual.: Surrogate recoveries below established limits
VSH Val. Qual.: Surrogate recoveries above established limits
VSG Val. Qual.: A silica gel cleanup procedure was performed
VS Val. Qual.: Sample Receipt nonconformance
VRL Val. Qual.: The MQL is above the regulatory limit
VRB Val. Qual.: Analyte detected in assoc. equipment rinsate blank
VR Val. Qual.: Rejected value
VQU Val. Qual.: Non-detect above PQL; final result is now PQL
VQT Val. Qual.: QA/QC protocols not met for instr.12-hr tuning crit.
VQS Val. Qual.: QA/QC protocols not met for surrogate recovery
VQQ Val. Qual.: PQL approx. due to QC or matrix effects
VQN Val. Qual.: QC data does not exist (hist. data) or is unavailable
VQM Val. Qual.: QA/QC protocols not met for matrix spike/spike dup.
VQL Val. Qual.: QA/QC protocols not met for lab control sample
VQI Val. Qual.: QA/QC protocols not met for internal standard
VQH Val. Qual.: QA/QC protocols not met for holding times
VQC Val. Qual.: QA/QC protocols not met for calibration
VQB Val. Qual.: QA/QC protocols not met for method blank
VQ Val. Qual.: QA/QC protocols were not met
VPL Val. Qual.: Post prep. spike recoveries below established limits
VPH Val. Qual.: Post prep. spike recoveries above established limits
VPA Val. Qual.: Possible biogenic interference in detect. hydrocarbs.
VP Val. Qual.: Sample Chromat. pattern does not match calib. pattern
VNB Val. Qual.: Result bias cannot be determined
VN Val. Qual.: Identification of compound is tentative
VMS Val. Qual.: Lboratory did not achieve required method sensitity.
VML Val. Qual.: Matrix spike recoveries below established limits
VMH Val. Qual.: Matrix spike recoveries above established limits
VMD Val. Qual.: Matrix Spike dup. RPD outside of established limits
VMB Val. Qual.: Analyte detected in associated method blank
VM Val. Qual.: Nonconformance due to matrix effects
VLL Val. Qual.: Lab control sample recoveries below estab. limits
VLH Val. Qual.: Lab control sample recoveries above estab. limits